<?xml version="1.0" encoding="UTF-8"?><Specimen xmlns="http://hl7.org/fhir"><id value="vma-urine"/><text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: Specimen</b><a name="vma-urine"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Specimen &quot;vma-urine&quot; </p></div><p><b>accessionIdentifier</b>: id: X352356</p><p><b>status</b>: available</p><p><b>type</b>: Urine, Random <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v2-0487.html">specimenType</a>#RANDU)</span></p><p><b>subject</b>: <a href="patient-example.html">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>receivedTime</b>: 2015-08-18T07:03:00Z</p><h3>Collections</h3><table class="grid"><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td><a href="practitioner-example-f202-lm.html">Practitioner/f202</a> &quot;Luigi Maas&quot;</td><td><span title="  the time of collection is usually required. Usually a point in time, but can be a period 
      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)  ">2015-08-18T07:03:00Z</span></td></tr></table><h3>Processings</h3><table class="grid"><tr><td>-</td><td><b>Description</b></td><td><b>Method</b></td><td><b>Additive</b></td><td><b>Time[x]</b></td></tr><tr><td>*</td><td>Acidify to pH &lt; 3.0 with 6 N HCl.</td><td>Acidification <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v2-0373.html">treatment</a>#ACID)</span></td><td><span>: 6 N HCl</span></td><td>2015-08-18T08:10:00Z</td></tr></table><h3>Containers</h3><table class="grid"><tr><td>-</td><td><b>Device</b></td><td><b>SpecimenQuantity</b></td></tr><tr><td>*</td><td><a href="device-example-specimen-container-polycup.html">Device/device-example-specimen-container-polycup</a></td><td>10 mls</td></tr></table></div></text><accessionIdentifier>  <!--    accession identifier - e.g. assigned by the labaratory when it is received.
     This is common, unlike specimen identifier    --><system value="http://lab.acme.org/specimens/2015"/><value value="X352356"/></accessionIdentifier><status value="available"/><type>  <!--   
   Type is a loosely defined field because there is such a lot of variation in how it is used.
   The principal variation is how much information that could be represented elsewhere is also
   represented here. For instance, here's some possible types:
     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)
     transfusion bag of blood (+ container.type)
     Peritoneal lavage        (+ collection.bodySite)
   If the type includes other fields, it would be normal not to populate the other fields

   Note that this practice is so widespread that it's pointless to try and stop it
    --><coding><system value="http://terminology.hl7.org/CodeSystem/v2-0487"/><code value="RANDU"/><display value="Urine, Random"/></coding></type><subject><reference value="Patient/example"/></subject><receivedTime value="2015-08-18T07:03:00Z"/>  <!--    method is usually implied by type    --><collection><collector>  <!--    in practice, collecter is almost always recorded    --><reference value="Practitioner/f202"/></collector>  <!--    the time of collection is usually required. Usually a point in time, but can be a period 
      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)    --><collectedDateTime value="2015-08-18T07:03:00Z"/></collection><processing><description value="Acidify to pH &lt; 3.0 with 6 N HCl."/><method><coding><system value="http://terminology.hl7.org/CodeSystem/v2-0373"/><code value="ACID"/></coding></method><additive><display value="6 N HCl"/></additive><timeDateTime value="2015-08-18T08:10:00Z"/></processing><container><device><reference value="Device/device-example-specimen-container-polycup"/></device><specimenQuantity><value value="10"/><unit value="mls"/></specimenQuantity></container></Specimen>