{"conformsTo":[{"specification":{"coding":[{"code":"528392","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"},"version":"1"}],"id":"ANDThermometer","identifier":[{"system":"urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680","type":{"coding":[{"code":"SYSID","display":"System Identifier","system":"http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"}]},"value":"54-4A-16-FF-FE-32-12-26"},{"system":"http://hl7.org/fhir/sid/eui-48","type":{"coding":[{"code":"BTMAC","display":"Bluetooth Address","system":"http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"}]},"value":"54-4A-16-32-12-26"}],"manufacturer":"A&D Medical","modelNumber":"UT-201BLE-A","name":[{"type":"user-friendly-name","value":"A&D_UT201BLEA_321226"}],"property":[{"type":{"coding":[{"code":"532353","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"},"valueCodeableConcept":{"coding":[{"code":"32776","system":"http://terminology.hl7.org/CodeSystem/ContinuaPAN"}]}},{"type":{"coding":[{"code":"532354.0","display":"regulation-status","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}]},"valueCodeableConcept":{"coding":[{"code":"N","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"Device is Regulated"}},{"type":{"coding":[{"code":"68220","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"},"valueCodeableConcept":{"coding":[{"code":"532224","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_SYNC_NONE: No time synchronization"}},{"type":{"coding":[{"code":"68219.0","display":"mds-time-capab-real-time-clock","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}]},"valueCodeableConcept":{"coding":[{"code":"Y","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"real time clock supported"}},{"type":{"coding":[{"code":"68219.1","display":"mds-time-capab-set-clock","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}]},"valueCodeableConcept":{"coding":[{"code":"Y","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"setting the time supported"}}],"resourceType":"Device","serialNumber":"5160800011","text":{"div":"<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"ANDThermometer\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;ANDThermometer&quot; </p></div><p><b>identifier</b>: System Identifier: 54-4A-16-FF-FE-32-12-26, Bluetooth Address: 54-4A-16-32-12-26</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>92677176693286</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)92677176693286(21)5160800011</td><td>unknown</td></tr></table><p><b>manufacturer</b>: A&amp;D Medical</p><p><b>serialNumber</b>: 5160800011</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>A&amp;D_UT201BLEA_321226</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: UT-201BLE-A</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: HTP009_137</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></p><p><b>value</b>: 4.1</p></blockquote><h3>ConformsTos</h3><table class=\"grid\"><tr><td>-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528392)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 32776 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#32776)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>","status":"generated"},"type":[{"coding":[{"code":"65573","display":"MDC_MOC_VMS_MDS_SIMP","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_MOC_VMS_MDS_SIMP: Personal Health Device"}],"udiCarrier":[{"carrierHRF":"(01)92677176693286(21)5160800011","deviceIdentifier":"92677176693286","entryType":"unknown","issuer":"http://hl7.org/fhir/NamingSystem/gs1-di","jurisdiction":"http://hl7.org/fhir/NamingSystem/fda-udi"}],"version":[{"type":{"coding":[{"code":"531976","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_ID_PROD_SPEC_FW: Firmware revision"},"value":"HTP009_137"},{"type":{"coding":[{"code":"531975","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_ID_PROD_SPEC_SW: Software revision"},"value":"0.00"},{"type":{"coding":[{"code":"531974","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_ID_PROD_SPEC_HW: Hardware revision"},"value":"0.00"},{"type":{"coding":[{"code":"532352","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"},"value":"4.1"}]}